kirby lantern

Kirby Lantern
Tungsten And Mercury



The Kirby is a low priced lantern with good daylight appearance for 60/200W GLS tungsten or for 80/125W mercury discharge lamps, Types MB/U or MBF/U. It is made in four versions offering alternative forms of light control.


Application
For Group 'B' roads.


Specification
The canopy is die-cast from LM-6-M silicon aluminium alloy and finished inside and out in 'aluminium paint'. There is adequate movement space inside for mains connection. An earth terminal and grub screw to secure to a bracket are fitted. The internal reflector plate is anodised aluminium. The hinge-pin is stainless steel. The pin securing the neat latch between canopy and bowl is phosphor bonze, selected to give reliable service for many years.


Light Distribution
Overall height 11 3/8" (28-9 cm) diameter 10 1/8" (25-7 cm). Top entry tapping ¾" BSP. Weight of lantern without glass refractor dome 4½ lbs. (2.0 kg). Weight of lantern with glass refractor dome 6½ lbs (2.8 kg).


Catalogue Numbers
Cat. Nos. Lamp Lampholder
Refractor dome with stippled 'Perspex' bowl
52/62612150/200W GLSES
52/6181280/125 MB/U, MFB/U3-pin BC
52/6101960/150W GLSBC
Opal 'Perspex' bowl without refractor
52/62613150/200W GLSES
52/6181380/125 MB/U, MFB/U3-pin BC
52/6102060/150W GLSBC
'Oroglass' refractor bowl
52/62614150/200W GLSES
52/6181480/125 MB/U, MFB/U3-pin BC
52/6102160/150W GLSBC
Glass refractor dome only
52/62615150/200W GLSES
52/6181580/125 MB/U, MFB/U3-pin BC
52/6102260/150W GLSBC


52/62612, 52/61812, 52/61019
A glass refractor dome enclosed by a stippled 'Perspex' bowl provides 2-way non-axial asymmetrical distribution.

52/62613, 52/61813, 52/61020
An 030 Opal 'Perspex' bowl provides a broad distribution.





52/62614




52/62613




52/62612




52/62615



Light Output
Lamp Watts
Lumen Rating

MB/U
125
4875

MB/U
80
2720

MBF/U
125
4900

MBF/U
80
2720
Total light output of lantern - lumens
Light output in lower hemisphere - lumens
Light output in upper hemisphere - lumens
Total light output ratio
Percentage of lantern in lower hemisphere
Percentage of lantern output in upper hemisphere
Direction Intensity Ratio (B.S. - CP 1004)
3559
3097
462
73%
87%
13%
2.23
1986
1728
258
73%
87%
13%
2.23
3626
2937
689
74%
81%
19%
1.4
2013
1631
382
74%
81%
19%
1.4
Conversion Factors. Diagrams are drawn for average conditions of 125W MB/U and MFB/U lamps. For other conditions multiply by conversion factor.
Initial lamp output - clean lantern 1.350.761.350.76
Average lamp output - clean lantern 1.00.641.00.64

Light Distribtion data are only given for the guidance of the Lighting Engineer and represent the results of laboratory tests on a typical lantern taken from stock. The data are based on the lamp characteristics stated; if the latest lamp efficiency is different, the candela or lumen values should be calculated in direct propotion to the relative lamp lumens.


Polar Curves
Blue - 52/61812 lantern with 125W MFB/U colour corrected mercury lamp.
Black - 52/61812 lantern with 125W MB/U mercury discharge lamp.

Polar curve of candlepower in a vertical plane through the main beam at 5o/175o azimuth.
Polar curve of candlepower in a cone at 75o to the downward vertical.




Showing curves of equal candle power from a 125W MB/U lamp of average efficiency.



Showing curves of equal candle power from a 125W MBF/U lamp of average efficiency.



Showing curves of equal candle power from a 200W GLS lamp of average efficiency.


Light Output Lamp (GLS) watts
Lumen Rating
200
2720
150
1960
100
1260
Total light output of lantern - lumens
Light output in lower hemisphere - lumens
Light output in upper hemisphere - lumens
Total light output ratio
Percentage of lantern in lower hemisphere
Percentage of lantern output in upper hemisphere
Direction Intensity Ratio (B.S. - CP 1004)
2159
1995
164
79%
92%
8%
2.13
1556
1438
118
79%
92%
8%
2.13
1000
924
76
79%
92%
8%
2.13
Conversion Factors. Diagrams are drawn for average conditions of 200W GLS lamp. For other conditions multiply by conversion factor.
Initial lamp output - clean lantern 1.060.760.49
Average lamp output - clean lantern 1.00.720.46

Light Distribtion data are only given for the guidance of the Lighting Engineer and represent the results of laboratory tests on a typical lantern taken from stock. The data are based on the lamp characteristics stated; if the latest lamp efficiency is different, the candela or lumen values should be calculated in direct propotion to the relative lamp lumens.


Polar Curves

Polar curve of candlepower in a vertical plane through the main beam at 5o/175o azimuth.
Polar curve of candlepower in a cone at 75o to the downward vertical.






Kirby Lantern with 'Diakon' Refractor Bowl




'Diakon' is a clear thermo-plastic, suitable for injection moulding and is virtually unbreakable. The refractor bowl used on the 'Kirby' is moulded in one piece by a tool the inner portion of which collapses to facilitate removal of the bowl and ensures accurately moulded prisms. Horizontal prisms are moulded on the inside of the bowl and vertical prisms on the outside, these are therefore self cleaning due to the washing action of rain. Hinge and catch blocks are moulded in position.

Light Distribution: two way non-axial.

Mercury Lamps: only the 80W MBF/U lamp should be used in 52/61814.

Tungsten Lamps: 60/150 watt GLS.


Showing curves of equal candle power from an 80W MBF/U lamp of average efficiency.


Light Output Lamp watts
Lumen Rating
80W MFB/U
2720
Total light output of lantern - lumens
Light output in lower hemisphere - lumens
Light output in upper hemisphere - lumens
Total light output ratio
Percentage of lantern in lower hemisphere
Percentage of lantern output in upper hemisphere
Direction Intensity Ratio (B.S. - CP 1004)
2162
1844
318
79.5%
85.3%
14.7%
2.12
Conversion Factors. Diagrams are drawn for average conditions of 80W MBF/U lamp. For other conditions multiply by conversion factor.
Initial lamp output - clean lantern 1.14
Average lamp output - clean lantern 1.0

Light Distribtion data are only given for the guidance of the Lighting Engineer and represent the results of laboratory tests on a typical lantern taken from stock. The data are based on the lamp characteristics stated; if the latest lamp efficiency is different, the candela or lumen values should be calculated in direct propotion to the relative lamp lumens.


Polar Curves

Polar curve of candlepower in a vertical plane through the main beam at 10o/170o azimuth.
Polar curve of candlepower in a cone at 72o to the downward vertical.




Showing curves of equal candle power from an 150W GLS lamp of average efficiency.


Light Output
Lamp Watts
Lumen Rating

150W GLS
1960

100W GLS
1260
Total light output of lantern - lumens
Light output in lower hemisphere - lumens
Light output in upper hemisphere - lumens
Total light output ratio
Percentage of lantern in lower hemisphere
Percentage of lantern output in upper hemisphere
Direction Intensity Ratio (B.S. - CP 1004)
1486
1328
158
75.8%
89.4%
10.6%
3.8
955
854
101
75.8%
89.4%
10.6%
3.8
Conversion Factors. Diagrams are drawn for average conditions of 150W GLS lamps. For other conditions multiply by conversion factor.
Initial lamp output - clean lantern 1.050.68
Average lamp output - clean lantern 1.00.64

Light Distribtion data are only given for the guidance of the Lighting Engineer and represent the results of laboratory tests on a typical lantern taken from stock. The data are based on the lamp characteristics stated; if the latest lamp efficiency is different, the candela or lumen values should be calculated in direct propotion to the relative lamp lumens.


Polar Curves

Polar curve of candlepower in a vertical plane through the main beam at 12o/168o azimuth.
Polar curve of candlepower in a cone at 73o to the downward vertical.






Kirby Lantern with Glass Refractor Dome




The canopy is covered by the specification on page 1 except for the hinge and latch which are omitted.

The glass dome refractor gives 2-way non-axial distribution.

Polar Curves
A. In vertical plane through the main beam.
B. In a cone at 75o to the downward vertical at 5o/175o azimuth.

1. 'Kirby' lantern 52/61815 with 125W MBF/U lamp.
2. 'Kirby' lantern 52/62615 with 200W GLS pearl lamp.
3. 'Kirby' lantern 52/61815 with 125W MB/U lamp.


The company reserve the right without notice to change the design or the specification of equipment included in this publication and supplied by them.