Designed to use 250 or400 watt MBF/U Lamp

SPECIFICATION

Corrosion resistant die-cast aluminium alloy (LM6M) canopy and bowl ring: one piece heat resistant acyrlic bowl. Highly polished specular aluminium side reflectors manufactured from super purity magnesium-aluminium alloy, chemically brightened and anodised. Inside of canopy stoved white, fully gasketted with neoprene strip to eliminate dirst and moisture; fitted porcelain terminal block, earth screw and cable clamp. Porcelain G.E.S. lampholder with heat resisting leads. Stainless steel hinge pins and quick action spring clips.

Compiles with B.S. 1877:1964

PERFORMANCE

Semi-cut-off distribution, 250 Watt, suitable for groups A1, A2 and A3 roads at 10m mounting height. 400 Watt, suitable for groups A1, A2 and A3 roads up to and including 12m mounting height. In accordance with British Standard Code of Practice CP 1004 Part 2: 1963.

LIGHT DISTRIBUTION DATA

Candela - Intensity ratio x 1090 M.H.I. Based on average output of 11,500 Lumens. Large scale Iso-Candle Diagrams and Polar Curves availabel on request. ELECO PHOTOMETRIC LABORATORY.

Candelas = Intensity ratio x 1865 M.H.I. Based on average output of 20,000 Lumens.

Photometric Data SR 304
Semi-cut-off
B.S.
1788:1964
250 WATT MBF/U 400 WATT MBF/U
Downward light output ratio 81% 80%
Angle of elevation
    Upper limit of beam
    Lower limit of beam

78°
66°

75°
63°

76° must be within beam
Peak intensity ratio 3.15 2.175 1.8 - 4.0
Maximum and minimum intensity ratios in the zone from the downward vertical to 30° therefrom 1.44
1.20
1.40
1.26
not to exceed 1.7
not less than 0.8
Angle of elevation at which the intensity ratio is 1.2 in the vertical plane parallel to the street axis
83°

81°

between 78°-84°
Intensity ratio at the horizontal in the vertical plane parallel to the street axis
.100

.103

not to exceed 0.6
Angle of Azimith between beam centre and road axis




not to exceed 15°
Light output in lower hemisphere (downward flux lumens)
9,315

16,000
See CP 1004 Part 2 1963 tables