Phosware Enclosed Pendant Lanterns

For Group "B" Street Lighting


P 104 Perspex Bowl Type

P 132 Prismatic Bowl Type



Phosware enclosed pendant lanterns for Group "B" lighting are made in two types: No P.104 with an internal two-way Dome refractor and a clear outer Perspex Bowl and No. P.132 which is fitted with an outer two-way glass prismatic Bowl for the light control.

Both types are suitable for the same range of lamps 100-200W GLS or 80-125W Mercury.

The Hood is of cast aluminium-alloy with a cast hinged ring which carries the bowl.

The interior of the hood is fitted with two downrods on which slides an adjustable cast bridge piece carrying the lampholder. This is common to both types.

With the P.104 a further 3-arm casting is fitted to the base of the hood to carry the two-way glass dome refractor and this is so arranged that it can only be placed in one position relative to the lantern, the hood being marked for the across road direction.

The dome refractor is held in its housing by 3 spring loaded hooks and is easily detachable for maintenance.

With the P.132 no internal refractor is necessary as the light control is effected by the prism construction of the bowl itself.

Standard Finish: Exterior, Hammered Metallic Beige; interior, white enammelled.

Light centre position, below top of glass refractor - P.104 Dome - 2 13/16", P.132 Bowl - 1 7/8"


List No. Type For Lamps Watts Dimensions ins. Weight lbs. Boss Tapped
Height Diameter
P.104 Enclosed 100-200W GLS or
80-125W MB/U or
80-125W MBF/U
12½ 10 ¾ or 1" BSP
P.132 11 5/8 10




Polar Distribution Curve OF Phosware P104 With 150W GLS Lamp Plotted To Lamp Output 2090 Lumens



Polar Distribution Curve OF Phosware P132 With 80W MB/U Mercury Lamp Plotted To Lamp Output 3000 Lumens




Lamp 100W 150W 200W 80W MB 125W MB
Initial Lamp lumens 1200 2090 2880 3000 5300
Average output throughout life 1160 1970 2725 2350 3900
Average output of lantern throughout life of lamp 870 1480 2040 1760 2920
Lumens per 100 ft. of road at 120 ft. spacing 725 1230 1700 1465 2430
Light output ratio 75%
Proportion in lower hemisphere 88%
Directional intensity ratio 1.9